SECO-LARM SA-027WQ Spécifications Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
ENFORCER 7-Day Timer
2 SECO-LARM U.S.A., Inc
Operating voltage
12~24 VAC/VDC
15mA@12VDC
70mA@12VDC
Relay rating
10A@120VAC/28VDC
Backup battery
1 x CR-2016 (included)
Weight
4.6-oz (130g)
Dimensions
4
3
/
16
” x 3
1
/
16
” x 1
1
/
4
(107 x 78 x 31 mm)
Specifications:
Overview:
Table of Contents:
Overview ....................................................... 2
Specifications ................................................ 2
Dimensions.................................................... 2
Installation ..................................................... 3
Setting the Security Code ............................. 3
Setting the Time ............................................ 4
Entering Events .......................................... 4-6
Setting Holiday Mode .................................... 6
Sample Applications/Wire Diagram .............. 7
Troubleshooting ............................................ 8
Dimensions:
LCD Display:
Power Indicator LED
Glows blue when power is ON.
Relay Indicator LED
Glows red when relay is active.
MODE
Enter mode selection
Toggle Automatic (relay will follow
programs) / Manual (relay will not
follow programs)
Hold 3-sec: Relay will exit
mode selection
RESET
Press once: Turn off relay
Hold 3-sec: Reset to factory defaults
SET See Programming section for details
Enter settings mode / Move to
previous setting.
CODE Security code setting
HOLI Holiday mode setting
ON Relay is ON
OFF Relay is OFF
NOTE: If both ON & OFF show, event is
programmed to Pulse mode.
AM / PM Indicates when set in 12-hr clock format
Event # Shows which event is active, or F/P for relay output mode
(+)
()
N.C.
COM
N.O.
N.O.
GND
Power Input
12~24 VAC/VDC
Relay Output
N.O.
Egress Input
SU-SA Day of the week
TIME Time setting
PROG Event program setting
Indicates time (hours:minutes)
4
9
/
16
(116mm)
3
1
/
16
(78mm)
1
1
/
4
(31mm)
4
3
/
16
(107mm)
ENTER See Programming section for details
Enter setting / Confirm setting /
Move to next setting.
DOWN See Programming section for details
Move to previous setting / Decrease
selected setting.
UP See Programming section for details
Move to next setting / Increase
selected setting.
LCD Display
See detailed description below.
Terminal block
For connection details, see Sample
Applications/Wire Diagram on
page 7.
Vue de la page 1
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire